AV Sensors

Media-Isolated Stainless Steel Pressure Sensors

CHT-19FS Non-Oil-Filled 19 mm Flush-Surface Medical Pressure Sensor

CHT-19FS Series

CHT-19FS Series

Non-oil-filled pressure sensor for intra-aortic balloon pumps

About the CHT-19FS

Non-oil-filled 19 mm flush-surface ceramic-hybrid sensor with normalized mV output. Designed for specialized medical pressure measurement, including helium-compatible IABP applications.

CHT-19FS Series Features

- Compatible with Medical Helium Gases

- Temperature Compensated

- Constant Voltage Excitation

- Gage Pressures

- mV Output

- Flange O Ring Port

- Normalized 100mV output

- High Linear Output

Suggested Applications

Intra-Aortic Balloon Pump Drive-Pressure Monitoring

The CHT-19FS is intended to measure the pneumatic drive pressure used to inflate and deflate an intra-aortic balloon. Its flush sensing surface and non-oil-filled construction are important where rapid pneumatic pressure changes must be measured without introducing an oil-filled isolation cavity. The pump controller can use the pressure waveform to supervise operation of the balloon-drive system.

IABP Pneumatic-Circuit Diagnostics

Pressure measurement within the helium-drive circuit can support equipment diagnostics by showing whether commanded inflation and deflation cycles produce the expected pressure response. Changes in waveform shape, peak pressure or pressure decay may help the equipment identify leaks, restrictions or abnormal pneumatic operation. This pressure feedback can support device-level diagnostic and alarm functions for the pneumatic drive system.

IABP Manufacturing and Service Verification

The sensor can be incorporated into manufacturing or service equipment used to verify the pneumatic performance of an intra-aortic balloon pump. Test software can compare measured pressure cycles with defined acceptance limits during assembly, calibration or maintenance. The flush, non-oil-filled sensing architecture supports repeatable evaluation of the rapid pressure cycles used by the IABP pneumatic system.

Why Choose the CHT-19FS Series

Choose the CHT-19FS when the application requires a non-oil-filled, flush-surface sensor for specialized medical pressure measurement. Its helium-compatible configuration and normalized output make it particularly suited to intra-aortic balloon pump pressure-sensing systems.

SPECIFICATIONS

Performance

Pressure NonLinearity

±0.25 %FSS

Stability

±0.25 %FSS (Over 1 Year)

Hysteresis & Repeatabillity

±0.05 %FSS (Typical)

Rise Time

0.1 mS

Thermal

Operating Temperature

-40 to 120 ̊F

Compensated Temperature

32 to 120 ̊F

Thermal Error, Offset

±0.4 %FSS (Typical)

Thermal Error, Span

± 0.4 %FSS

Maximum Ratings

Excitation

10 Vdc

Storage Temperature

-40 to 165 ̊F

Over Pressure

5x Range

Media Compatibility

Gases compatible with 316L

Electrical

Output

100 mV

Offset

±2.5 mV

Bridge Resistance

1250 to 6100 Ω

Connections

5 Pin Molex C Conn.

Model Number Configuration

Mechanical Dimensions

Urban

Contact Our Sales Team

Have questions? Need a quote? We are ready to help as a member of our sales team will contact you to discuss your requirements. 

bottom of page