top of page
Anchor 1-Board Mount
MCT-ASCX Series

MCT-ASCX Series

(MCT) Multi Chip Technology

Analog Voltage Output, Sensym Compatible ASCX Sensor, 1.5% TEB High Accuracy, Plastic Ported, 5/32 Tube

Features

- Integrated PCB Board Mounting Holes

- Analog Voltage Output

- Vertical Top Port Smooth Pressure Ports

- Thru Hole

- ASIC Compensation

- 1.5% Total Error Band (TEB)

- 0.25 to 4.75Vdc Output

- Sensor Diagnostics for Medical Applications

Great for .....

Semiconductor Instruments

Diagnostic Instruments

About the MCT-ASCX

Advanced Sensors Multi Chip Technology (MCT) 24ASCX Series incorporates a bonded silicon gage to the latest
mixed signal ASIC (Application Specific Integrated Circuit) Designed as pin to pin compatible design for Sensym’s Iconic ASCX series, the AVSensors MCT-24ASCX series is designed with latest mixed signal ASIC providing a superior performance provides 1.5% Total Error across a wide temperature range of 0 to 70°C. The ASIC’s advanced design allows for the sensor output to be limited for safety critical operations with internal error checking of the sensor’s input and output lines.

SPECIFICATIONS

Performance

Total Error Band

±1.5 %FSS

ENOB

~12 Bits

Update Time

2Khz

Calibration

2nd Order Offset or Sensitivity

Thermal

Operating Temperature

-40 to 125 ̊C

Compensated Temperature

-0 to 70C

Thermal Error, Offset

±0.4 %FSS (Typ)

Thermal Error, Span

± 0.2 %FSS

Electrical

Output

Analog Voltage, 4.0/4.5 VDC (5.0 Vdd)

Excitation

3.3 or 5.0 Vdc

Offset

10% or 5% Vdd

Full Scale Span

80% or 90% Vdd

Maximium Ratings

Excitation

5.5Vdc

Storage Temperature

-50 to 150 ̊C

Over Pressure

5x Range

Media Comptabilty

Non Corrosive Gases

Model Number Configuration

Mechanical Dimensions

MCT-ASCX Series

Application Notes

MCT-ASCX Series

Describes key pressure sensor performance metrics such as accuracy, range, and reference type, explaining how these specs relate to system requirements. It aids engineers in interpreting datasheet values to choose the right sensor

MCT-ASCX Series

This note reviews practical methods for compensating temperature-dependent performance shifts in piezoresistive pressure sensors. It also references AVSensors’ factory-calibrated, thermally compensated models as application options.

MCT-ASCX Series

Defines the three primary pressure measurement types and shows how each reflects different reference conditions in an application. It highlights when to use each sensor type based on design needs.

Contact Our Sales Team

Have questions? Need a quote? We are ready to help as a member of our sales team will

contact you to discuss your requirements. 