top of page
Anchor 1-Board Mount
MCT-MPX Series

MCT-MPX Series

(MCT) Multi Chip Technology

Analog Voltage Output, 0.2 to 4.7Vdc, Dual Ports

Features

- Replacement for MPX Unibody

- 0.2 to 4.7Vdc Ratiometric Output

- Ports In Line with Pin Connections

- Temperature Compensated

- ASIC Compensation

- 2.0% Total Error Band (TEB)

- Ratiometric Output

- Constant Voltage Excitation

Great for .....

Medical Instrumentation

Process or Instrument Control

Pneumatic Controls

About the MCT-MPX

Advanced Sensors Multi Chip Technology (MCT) MPX Series was designed as a drop in replacement for Motorola MPX Unibody (Case 867) series of pressure transducers. The design incorporates the latest mixed signal ASIC (Application Specific Integrated Circuit) with a bonded silicon gage to provide a high level analog output for medical, life science and pneumatic control industries. The designs superior performance provides 2% Total Error across a wide temperature range of -0 to 60°C. The MCT-MPX series is the ideal choice for OEM customers needing a direct replacement of Motorola MPX Series.

SPECIFICATIONS

Performance

Total Error Band

±2.0 %FSS

ENOB

~12 Bits

Update Time

2Khz

Calibration

2nd Order Offset or Sensitivity

Thermal

Operating Temperature

-40 to 125 ̊C

Compensated Temperature

0 to 60 ̊C

Thermal Error, Offset

±0.4 %FSS (Typ)

Thermal Error, Span

± 0.2 %FSS

Electrical

Output

Analog Voltage, 0.2 to 4.7 VDC (5.0 Vdd)

Excitation

3.3 or 5.0 Vdc

Offset

4% Vdd

Full Scale Span

95% Vdd

Maximium Ratings

Excitation

5.5Vdc

Storage Temperature

-40 to 125 ̊C

Over Pressure

5x Range

Media Comptabilty

Non Corrosive Gases

Model Number Configuration

Mechanical Dimensions

MCT-MPX Series

Application Notes

MCT-MPX Series

This note reviews practical methods for compensating temperature-dependent performance shifts in piezoresistive pressure sensors. It also references AVSensors’ factory-calibrated, thermally compensated models as application options.

MCT-MPX Series

Describes key pressure sensor performance metrics such as accuracy, range, and reference type, explaining how these specs relate to system requirements. It aids engineers in interpreting datasheet values to choose the right sensor

MCT-MPX Series

Defines the three primary pressure measurement types and shows how each reflects different reference conditions in an application. It highlights when to use each sensor type based on design needs.

Contact Our Sales Team

Have questions? Need a quote? We are ready to help as a member of our sales team will

contact you to discuss your requirements. 

Urban